{"id":117,"date":"2023-12-06T15:17:21","date_gmt":"2023-12-06T14:17:21","guid":{"rendered":"https:\/\/epmc2.fr\/?page_id=117"},"modified":"2023-12-09T17:16:33","modified_gmt":"2023-12-09T16:16:33","slug":"les-principaux-standards","status":"publish","type":"page","link":"https:\/\/epmc2.fr\/index.php\/les-principaux-standards\/","title":{"rendered":"Les principaux standards"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Les Principaux standards utilis\u00e9s<\/h3>\n\n\n\n<p>Il existe aujourd\u2019hui cinq m\u00e9thodes de mesure de la taille fonctionnelle en points de fonction (FSM \u2013 Functional Size Measurement) approuv\u00e9es par l\u2019International Organisation for Standardisation (ISO)&nbsp;:<\/p>\n\n\n\n<p><strong>IFPUG FPA f.4.3<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>ISO\/IEC 20926 : 2009 &#8211; Information technology &#8212; Software and systems engineering &#8211;\u2014 Software measurement \u2014 IFPUG functional size measurement method 2009<\/li>\n<\/ul>\n\n\n\n<p><strong>NESMA FPA&nbsp;V 2.0<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>ISO\/IEC 24570:2005 &#8211; Information technology &#8212; Software and systems engineering &#8212; NESMA functional size measurement method version 2.1 &#8211; Definitions and counting guidelines for the application of Function Point Analysis<\/li>\n<\/ul>\n\n\n\n<p><strong>Mark II FPA r.1.3.1<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>ISO\/IEC 20968:2002 &#8211; Software engineering \u2013 Mk II Function Point Analysis &#8211; Counting Practices Manual<\/li>\n<\/ul>\n\n\n\n<p><strong>COSMIC FSM r.3.0.1<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>ISO\/IEC 19761:2009 &#8211; Information technology &#8212; Software and systems engineering &#8212;- COSMIC-FFP &#8212; A functional size measurement method<\/li>\n<\/ul>\n\n\n\n<p><strong>FiSMA FSM 1.1<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>ISO\/IEC 29881:2008 &#8211; Information technology &#8212; Software and systems engineering &#8212; FiSMA 1.1 functional size measurement method<\/li>\n<\/ul>\n\n\n\n<p>L\u2019ISO a r\u00e9cemment publier un guide qui indique comment choisir la m\u00e9thode la mieux adapt\u00e9e \u00e0 vos propres besoins. Il en ressort que les points clefs \u00e0 prendre en consid\u00e9ration sont les suivants&nbsp;:<\/p>\n\n\n\n<p>&nbsp;\u2022&nbsp; A titre indicatif les organisations qui d\u00e9veloppent ou utilisent les applications riches en donn\u00e9es de type syst\u00e8mes d\u2019information de gestion, les services bancaires, financiers, CRM (GRC), Asset Management (Gestion d\u2019actifs), les syst\u00e8mes de Work flow, etc \u2026) utilisent de pr\u00e9f\u00e9rence la m\u00e9thode IFPUG. Les organisations qui d\u00e9veloppement ou utilisent les logiciels \u00e0 process complexes et applications temps r\u00e9el tendent \u00e0 utiliser plut\u00f4t la m\u00e9thode COSMIC.&nbsp;<\/p>\n\n\n\n<p>\u2022 90 % des projets \u00e9valu\u00e9s et disponible dans la base de l\u2019 ISBSG sont \u00e9valu\u00e9s avec la m\u00e9thode IFPUG. La m\u00e9thode COSMIC voit croitre cependant son utilisation. &nbsp;<\/p>\n\n\n\n<p>\u2022 Les experts certifi\u00e9s sont principalement aujourd\u2019hui form\u00e9s \u00e0 la m\u00e9thode IFPUG, la certification COSMIC est cependant \u00e0 pr\u00e9sent elle aussi offerte en Europe, Am\u00e9rique du Nord et en Australie.<\/p>\n\n\n\n<p>\u2022&nbsp; Les formations et outils de FSM sont principalement orient\u00e9s IFPUG<\/p>\n\n\n\n<p>&nbsp;ISO\/IEC 14143-6: SOFTWARE ENGINEERING \u2014 SOFTWARE MEASUREMENT \u2014&nbsp; FUNCTIONAL SIZE MEASUREMENT \u2014 PART 6: GUIDE FOR USE OF ISO\/IEC 14143 SERIES AND RELATED INTERNATIONAL STANDARDS<\/p>\n\n\n\n<p>Ci-dessous un tableau de comparaison sur 38 crit\u00e8res diff\u00e9rents. Ce qu&#8217;il faut savoir c&#8217;est que l&#8217;IFPUG reste la r\u00e9f\u00e9rence sur le territoire national. Les grands donneurs d&#8217;ordre,&nbsp;majoritairement membres de l&#8217;ASSEMI (Association Fran\u00e7aise des M\u00e9triques Informatiques), Renault, PSA, SFR, Orange,&nbsp;Michelin, Soci\u00e9t\u00e9 G\u00e9n\u00e9rale, Banque de France, l&#8217;ensemble des Minist\u00e8res et l&#8217;administration fran\u00e7aise, ont mis en oeuvre le standard IFPUG. Sachant que les standards pr\u00e9sent\u00e9s ci-dessous sont compatibles en terme de comptage&nbsp;avec l&#8217;IFPUG.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"604\" height=\"389\" src=\"https:\/\/epmc2.fr\/wp-content\/uploads\/2023\/12\/Standard1.jpg\" alt=\"\" class=\"wp-image-121\" srcset=\"https:\/\/epmc2.fr\/wp-content\/uploads\/2023\/12\/Standard1.jpg 604w, https:\/\/epmc2.fr\/wp-content\/uploads\/2023\/12\/Standard1-300x193.jpg 300w\" sizes=\"(max-width: 604px) 100vw, 604px\" \/><\/figure>\n\n\n\n<p><a href=\"https:\/\/cdn.simplesite.com\/i\/c0\/97\/283445309212039104\/i283445314525353084._szw1280h1280_.jpg\"><\/a><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"604\" height=\"382\" src=\"https:\/\/epmc2.fr\/wp-content\/uploads\/2023\/12\/Standard2.jpg\" alt=\"\" class=\"wp-image-122\" srcset=\"https:\/\/epmc2.fr\/wp-content\/uploads\/2023\/12\/Standard2.jpg 604w, https:\/\/epmc2.fr\/wp-content\/uploads\/2023\/12\/Standard2-300x190.jpg 300w\" sizes=\"(max-width: 604px) 100vw, 604px\" \/><\/figure>\n\n\n\n<p><a href=\"https:\/\/cdn.simplesite.com\/i\/c0\/97\/283445309212039104\/i283445314525353107._szw1280h1280_.jpg\"><\/a><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"604\" height=\"382\" src=\"https:\/\/epmc2.fr\/wp-content\/uploads\/2023\/12\/Standard-3.png.jpg\" alt=\"\" class=\"wp-image-123\" srcset=\"https:\/\/epmc2.fr\/wp-content\/uploads\/2023\/12\/Standard-3.png.jpg 604w, https:\/\/epmc2.fr\/wp-content\/uploads\/2023\/12\/Standard-3.png-300x190.jpg 300w\" sizes=\"(max-width: 604px) 100vw, 604px\" \/><\/figure>\n\n\n\n<p><a href=\"https:\/\/cdn.simplesite.com\/i\/c0\/97\/283445309212039104\/i283445314525353117._szw1280h1280_.jpg\"><\/a><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"604\" height=\"183\" src=\"https:\/\/epmc2.fr\/wp-content\/uploads\/2023\/12\/Standard4.jpg\" alt=\"\" class=\"wp-image-124\" srcset=\"https:\/\/epmc2.fr\/wp-content\/uploads\/2023\/12\/Standard4.jpg 604w, https:\/\/epmc2.fr\/wp-content\/uploads\/2023\/12\/Standard4-300x91.jpg 300w\" sizes=\"(max-width: 604px) 100vw, 604px\" \/><\/figure>\n\n\n\n<p><a href=\"https:\/\/cdn.simplesite.com\/i\/c0\/97\/283445309212039104\/i283445314525353126._szw1280h1280_.jpg\"><\/a><\/p>\n\n\n\n<h4 class=\"wp-block-heading\">FSM M\u00e9thodes compar\u00e9es<\/h4>\n\n\n\n<p>Un document bien utile r\u00e9alis\u00e9 par SMS qui compare les principales m\u00e9thodes.<\/p>\n\n\n\n<p><a href=\"http:\/\/epmc2.fr\/wp-content\/uploads\/2023\/12\/FSM-Methodes-comparees.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><mark style=\"background-color:rgb(247,229,151)\" class=\"has-inline-color has-kubio-color-1-color\">T\u00e9l\u00e9chargez fichier<\/mark><\/strong><\/a><\/p>\n\n\n\n<h4 class=\"wp-block-heading\">FSM Convertion des diff\u00e9rents standards<\/h4>\n\n\n\n<p>Une note de Luigi LAVAZZA qui donne des pistes int\u00e9ressantes sur la convertiblit\u00e9 des mod\u00e8les, dont COSMIC &amp; IFPUG. Luigi Lavazza est professeur \u00e0 l&#8217;Universit\u00e9 de Var\u00e8se d\u00e9partement informatique<\/p>\n\n\n\n<p><a href=\"http:\/\/epmc2.fr\/wp-content\/uploads\/2023\/12\/FSM-Convertion-des-differents-standards.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><mark style=\"background-color:rgb(247,229,151)\" class=\"has-inline-color has-kubio-color-1-color\">T\u00e9l\u00e9chargez fichier<\/mark><\/strong><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Les Principaux standards utilis\u00e9s Il existe aujourd\u2019hui cinq m\u00e9thodes de mesure de la taille fonctionnelle en points de fonction (FSM \u2013 Functional Size Measurement) approuv\u00e9es par l\u2019International Organisation for Standardisation (ISO)&nbsp;: IFPUG FPA f.4.3 NESMA FPA&nbsp;V 2.0 Mark II FPA r.1.3.1 COSMIC FSM r.3.0.1 FiSMA FSM 1.1 L\u2019ISO a r\u00e9cemment publier un guide qui indique [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"saved_in_kubio":true,"footnotes":""},"class_list":["post-117","page","type-page","status-publish","hentry"],"kubio_ai_page_context":{"short_desc":"","purpose":"general"},"_links":{"self":[{"href":"https:\/\/epmc2.fr\/index.php\/wp-json\/wp\/v2\/pages\/117","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/epmc2.fr\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/epmc2.fr\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/epmc2.fr\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/epmc2.fr\/index.php\/wp-json\/wp\/v2\/comments?post=117"}],"version-history":[{"count":6,"href":"https:\/\/epmc2.fr\/index.php\/wp-json\/wp\/v2\/pages\/117\/revisions"}],"predecessor-version":[{"id":245,"href":"https:\/\/epmc2.fr\/index.php\/wp-json\/wp\/v2\/pages\/117\/revisions\/245"}],"wp:attachment":[{"href":"https:\/\/epmc2.fr\/index.php\/wp-json\/wp\/v2\/media?parent=117"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}